British Skydiving has been advised that Aerodyne have issued Service Bulletin SB-300426, following recent consultation and ground testing carried out in the UK. Based on the information provided, British Skydiving is now authorising a partial lifting of the grounding for certain ICON container models, subject to specific conditions.
In summary:
The AAD cutter configuration outlined in SB-300426 must be completed and signed off by a British Skydiving Advanced Rigger
All work must be recorded on the ICON data card and Record of Inspection
Containers endorsed with SB210108 or TB250122 are considered compliant
ICON models I4/S4 through I9/S9 (including Nexgen and Pre-Nexgen systems) may return to use once compliant
ICON sizes I1 to I3 remain grounded until further notice
British Skydiving will continue to monitor the situation and issue further updates as required.